Inductive sensors

Total: 2307
Type Housing diameter (dimension) Power supply Rated operating distance Sn Function Mounting
Connection
Housing material Total length of the sensor
KS95 B0-O-N-Z-E M22x1 AC 2-WIRE (180-250V) 10mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC-CAW 84mm
KS95 A1-U-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 10mm NORMAL OPEN (NO) FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 97mm
KS95 B1-U-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 10mm NORMAL CLOSE (NC) FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 97mm
KS95 A1-U-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 10mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 97mm
KS95 B1-U-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 10mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 97mm
KS95 A1-O-60-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 72mm
KS95 B1-O-60-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 72mm
KS95 A1-O-60-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 72mm
KS95 B1-O-60-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 72mm
KS95 A1-O-95-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 107mm
KS95 B1-O-95-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 107mm
KS95 A1-O-95-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 107mm
KS95 B1-O-95-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 107mm
KS97 A1-O-60-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 72mm
KS97 B1-O-60-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 72mm
KS97 A1-O-60-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 72mm
KS97 B1-O-60-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 72mm
KS97 A1-O-95-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 107mm
KS97 B1-O-95-N-E-L5 M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 107mm
KS97 A1-O-95-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 107mm
KS97 B1-O-95-N-Z-E-L5 M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E CuZn NICKEL-PLATED 107mm
KS95 A1-O-N-E M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 95mm
KS95 B1-O-N-E M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 95mm
KS95 A1-O-N-Z-E M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 95mm
KS95 B1-O-N-Z-E M30x1,5 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 95mm
KS97 A1-O-N-E M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 95mm
KS97 B1-O-N-E M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 95mm
KS97 A1-O-N-Z-E M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 95mm
KS97 B1-O-N-Z-E M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 95mm
KS95 A2-O-N-E ø39/M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 97mm
KS95 B2-O-N-E ø39/M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 97mm
KS95 A2-O-N-Z-E ø39/M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 97mm
KS95 B2-O-N-Z-E ø39/M30x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E SPOLAMID 97mm
KS95 A3-O-N-E M40x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E PVC-CAW 72mm
KS95 B3-O-N-E M40x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E PVC-CAW 72mm
KS95 A3-O-N-Z-E M40x1,5 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC-CAW 72mm
KS95 B3-O-N-Z-E M40x1,5 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC-CAW 72mm
KS95 B3361-N-E 24x33x61 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E PVC 42552ac5091d8d44.24814564.gif
KS95 B3361-N-Z-E 24x33x61 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC 226552ac50945e4a7.83059874.gif
KS95 A7049-N-E 34x49x70 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E PVC 761552ac5096a1a86.36353085.gif
KS95 B7049-N-E 34x49x70 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E PVC 416552ac509705175.09707413.gif
KS95 A7049-N-Z-E 34x49x70 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC 635552ac509772ad7.88584383.gif
KS95 B7049-N-Z-E 34x49x70 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC 515552ac509803d82.12593190.gif
KS97 A7049-N-E 34x49x70 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E PVC 47552ac509894e11.30633488.gif
KS97 B7049-N-E 34x49x70 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E PVC 2552ac5098fbf95.05907493.gif
KS97 A7049-N-Z-E 34x49x70 AC 2-WIRE (180-250V) 20mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC 270552ac509967d46.31289313.gif
KS97 B7049-N-Z-E 34x49x70 AC 2-WIRE (180-250V) 20mm NORMAL CLOSE (NC) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC 548552ac5099c8dd1.30879909.gif
KS95 A9530-N-E 30x30x95 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) NON-FLUSH MOUNTED CONNECTOR E PVC-CAW 514552ac509a26056.52969699.gif
KS95 B9530-N-E 30x30x95 AC 2-WIRE (180-250V) 15mm NORMAL CLOSE (NC) NON-FLUSH MOUNTED CONNECTOR E PVC-CAW 981552ac509aca9a6.45982430.gif
KS95 A9530-N-Z-E 30x30x95 AC 2-WIRE (180-250V) 15mm NORMAL OPEN (NO) (SHORT-CIRCUIT-PROOF) NON-FLUSH MOUNTED CONNECTOR E PVC-CAW 385552ac509b393e6.03563022.gif