Type | Housing diameter (dimension) | Power supply | Rated operating distance Sn | Function | Mounting | Connection | Housing material | Total length of the sensor |
---|---|---|---|---|---|---|---|---|
KS95 D1-U-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 10mm | NORMAL CLOSE (NC) | FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 103mm |
KS95 CXD1-U-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 10mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 103mm |
KS95 C1-O-60-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 88mm |
KS95 D1-O-60-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 88mm |
KS95 CXD1-O-60-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 88mm |
KS95 C1-O-95-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 113mm |
KS95 D1-O-95-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 113mm |
KS95 CXD1-O-95-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 113mm |
KS97 C1-O-60-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 88mm |
KS97 D1-O-60-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 88mm |
KS97 CXD1-O-60-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 88mm |
KS97 C1-O-95-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 113mm |
KS97 D1-O-95-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 113mm |
KS97 CXD1-O-95-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | CuZn NICKEL-PLATED | 113mm |
KS95 C1-O-V2-K-50 | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 78mm |
KS95 D1-O-V2-K-50 | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 78mm |
KS95 CXD1-O-V2-K-50 | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 78mm |
KS95 C1-O-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 101mm |
KS95 D1-O-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 101mm |
KS95 CXD1-O-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 15mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 101mm |
KS97 C1-O-V2-K-50 | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 78mm |
KS97 D1-O-V2-K-50 | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 78mm |
KS97 CXD1-O-V2-K-50 | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 78mm |
KS97 C1-O-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 101mm |
KS97 D1-O-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 101mm |
KS97 CXD1-O-V2-K | M30x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | SPOLAMID | 101mm |
KS95 C3-O-V2-K | M40x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | PVC-CAW | 88mm |
KS95 D3-O-V2-K | M40x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | PVC-CAW | 88mm |
KS95 CXD3-O-V2-K | M40x1,5 | DC 2-WIRE(15-40V) | 20mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | PVC-CAW | 88mm |
KS04 C3-O-V2-K | M40x1,5 | DC 2-WIRE(15-40V) | 30mm | NORMAL OPEN (NO) | NON-FLUSH MOUNTED | CONNECTOR K | PVC-CAW | 88mm |
KS04 D3-O-V2-K | M40x1,5 | DC 2-WIRE(15-40V) | 30mm | NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR K | PVC-CAW | 88mm |
KS04 CXD3-O-V2-K | M40x1,5 | DC 2-WIRE(15-40V) | 30mm | NORMAL OPEN OR NORMAL CLOSE (NO/NC SELECTABLE) | NON-FLUSH MOUNTED | CONNECTOR K | PVC-CAW | 88mm |
KS95 D08/12-O-61-NPN-H | M8/M12x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR H | CuZn | 61mm |
KS95 D08/12-O-74-NPN-E | M8/M12x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR E | CuZn | 74mm |
KS95 D08/12-O-NPN-E | M8/M12x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR E | PVC-CAW | 70mm |
KS95 D08/12-O-NPN-H-57 | M8/M12x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR H | PVC-CAW | 57mm |
KS95 D08/12-U-57-NPN-H | M8/M12x1 | DC 3/4-WIRE(10-30V) | 1,5mm | NPN NORMAL CLOSE (NC) | FLUSH MOUNTED | CONNECTOR H | CuZn | 57mm |
KS95 D08/12-U-NPN-E | M8/M12x1 | DC 3/4-WIRE(10-30V) | 1,5mm | NPN NORMAL CLOSE (NC) | FLUSH MOUNTED | CONNECTOR E | CuZn | 70mm |
KS95 D08-O-35-NPN | M8x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | CuZn NICKEL-PLATED | 34mm |
KS95 D08-O-35-NPN-BZ | ø8 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | STAINLESS STEEL | 34mm |
KS95 D08-O-35-NPN-L | M8x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | CuZn NICKEL-PLATED | 34mm |
KS95 D08-O-35-NPN-L-BZ | ø8 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | STAINLESS STEEL | 34mm |
KS95 D08-O-40-NPN | M8x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | CuZn NICKEL-PLATED | 39mm |
KS95 D08-O-40-NPN-E | M8x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR E | CuZn NICKEL-PLATED | 39mm |
KS95 D08-O-40-NPN-L | M8x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | CuZn NICKEL-PLATED | 39mm |
KS95 D08-O-45-NPN | M8x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | CuZn NICKEL-PLATED | 44mm |
KS95 D08-O-45-NPN-BZ | ø8 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | STAINLESS STEEL | 44mm |
KS95 D08-O-45-NPN-E | M8x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CONNECTOR E | CuZn NICKEL-PLATED | 44mm |
KS95 D08-O-45-NPN-L | M8x1 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | CuZn NICKEL-PLATED | 44mm |
KS95 D08-O-45-NPN-L-BZ | ø8 | DC 3/4-WIRE(10-30V) | 2mm | NPN NORMAL CLOSE (NC) | NON-FLUSH MOUNTED | CABLE 2m | STAINLESS STEEL | 44mm |